Sign In | Join Free | My fazendomedia.com |
|
Brand Name : GFUVE
Model Number : LMCK185-10 5000A
Certification : IEC,ISO9001, UL, KEMA
Place of Origin : Beijing, China
MOQ : 3 Pieces
Price : Negotiable
Payment Terms : T/T, Western Union,Paypal
Supply Ability : 10000 Pieces Per Month
Delivery Time : 3 - 7 Days
Packaging Details : Standard Export Wooden Box
Accuracy Class : 0.5%, 1%
Standards : IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Range of primary rated current : 300-5000A
Range of Rated load : ≤25VA
Secondary winding power frequency withstand voltage : 3kV, 1min
Aperture (mm) : Φ185
Material : ABS and resin
Weight : 4.5KG
LMCK185-10 Resin cast IEC61869 Outdoor Current Transformer Split Core, Using in 10KV power line
Outdoor current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This Type is flame retardance anti-moisture, stable performance, no maintenance.
LMCK series outdoor current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case (ABS&PC) which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Technical parameters | |
Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006 |
Accuracy Class | 0.5%, 1% |
Range of primary rated current | 300-5000A |
Range of Rated load | ≤25VA |
Technical parameters - continued | |
Rated frequency | 50/60Hz |
Rated secondary current | 5A or 1A |
Secondary winding power frequency withstand voltage | 3kV, 1min |
Safety Factor Rating | (FS) <5 |
Flame retardant ABS plastic shell inside, jaw waterproof apron. | |
Mechanical parameters | |
Aperture (mm) | Φ185 |
Dimensions (W×D×H) (mm) | 350×283×55 |
Weight (kg) | 4.5 |
Working conditions | |
Operating temperature | -35°C to +55°C, not exceeding +40°C |
Environment | outdoors or indoors |
The height of above sea level | 0- 3000m |
Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed. |
Compare Datasheet
Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof |
LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 |
LMCK185-10 | 300-5000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) |
The Product Picture:
![]() |
Resin Cast IEC61869 Outdoor Current Transformer Split Core For 10KV Power Line Images |